Harmony SCU
HMISCU6A5
HMISCU6A5
3”5 color touch controller panel - Dig 16 inputs/10 outputs
Show more characteristics-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range of product Harmony SCUproduct or component type Small touch HMI controllerdisplay size 3.5 inchdisplay type Backlit LED colour TFT LCDtouch panel Analoguedevice presentation Complete productComplementary display resolution 320 x 240 pixels QVGAbacklight lifespan 50000 hours 65000 coloursbrightness 16 levels via touch panelview angle horiz x vert 60° left60° right40° top60° bottomcharacter font Japanese (ANK, Kanji)ASCIITaiwanese (traditional Chinese)KoreanChinese (simplified Chinese)supply External source[Us] rated supply voltage 24 V 20.4…28.8 V)DCimmunity to microbreaks 10 msinrush current 30 Apower consumption in W 15 Wlocal signalling No indicatornumber of pages Limited by internal memory capacitysoftware designation SoMachineoperating system Harmonyprocessor name CPU RISCprocessor frequency 333 MHzmemory description Flash NAND, 128 MBInternal data storage FRAM, 128 kBApplication run DRAM, 128 MBintegrated connection type 1 serial link - RJ45 - RS232/RS485 <= 115.2 kbits/s)1 Ethernet TCP/IP - RJ451 USB 2.0 type mini B1 USB 2.0 type A CANopen master bus - SUB-D 9realtime clock Built-indownloadable protocols CANopenModbus TCP/IPModbusfixing mode By 1 nut Ø 22 mm 1...6 mm thick panelenclosure material PC/PBTshock resistance 147 m/s² 11 ms on DIN rail)IEC 60068-2-27294 m/s² 6 ms on panel mounting)IEC 60068-2-27vibration resistance +/- 3.5 mm 5…9 Hz) IEC 60068-2-61 gn 9…150 Hz) IEC 60068-2-6electromagnetic compatibility Electrostatic discharge immunity test 8 kV air discharge) IEC 61000-4-2Electrostatic discharge immunity test 6 kV contact discharge) IEC 61000-4-2Susceptibility to electromagnetic fields 10 V/m 80 MHz...3 GHz) IEC 61000-4-3Electrical fast transient/burst immunity test 2 kV power lines) IEC 61000-4-4Electrical fast transient/burst immunity test 1 kV between analogue I/O and operating voltage) IEC 61000-4-4Electrical fast transient/burst immunity test 2 kV relay wires) IEC 61000-4-4Electrical fast transient/burst immunity test 1 kV Ethernet line) IEC 61000-4-4Electrical fast transient/burst immunity test 1 kV COM line) IEC 61000-4-4Electrical fast transient/burst immunity test 1 kV CAN line) IEC 61000-4-4Surge immunity test 2 kV power supply (common mode)) IEC 61000-4-5Surge immunity test 1 kV power supply (differential mode)) IEC 61000-4-5Surge immunity test 1 kV common mode digital I/O) IEC 61000-4-5Surge immunity test 0.5 kV differential mode digital I/O) IEC 61000-4-5Conducted RF disturbances 10 V 0.15...80 MHz) IEC 61000-4-6Conducted emission 150 kHz...30 MHz EN 55011Radiated emission 30 MHz...1 GHz EN 55011discrete input number 2 fast input (normal mode) IEC 61131-2 Type 114 digital input IEC 61131-2 Type 1discrete input voltage 24 V DC sink or source (positive/negative)number of common point 1 fast input (HSC mode)2 digital inputdiscrete input current 7.83 mA fast input5 mA digitalinput impedance 2.81 kOhm4.7 kOhmsensor power supply 15…28.8 V DC >= 15 V >= 5 mA <= 5 V <= 1.5 mA15…28.8 V DC >= 15 V >= 2.5 mA <= 5 V <= 1 mAconfigurable filtering time 0 ms no filter none)0.004...0.04 ms bounce filter latch/event and cumulative filter by step Nx0.5ms (64>=N>=2))3...12 ms integrator none/run/stop)maximum input frequency 100 kHz fast input (encoder mode) A/B100 kHz fast input single phase100 kHz fast input pulse/directionmaximum cable distance between devices Shielded cable <32.81 ft (10 m) fast inputShielded cable <328.08 ft (100 m) digital inputUnshielded cable <164.04 ft (50 m) digital inputconnection pitch 0.14 in (3.5 mm)overvoltage protection Withisolation between channels and internal logic 500 V DCisolation between channels Nonediscrete output number 2 fast output (normal mode) source8 digital output sourcediscrete output voltage 24 V DC 19.2...28.8 V)transistor24 V DC 5...30 V)relay220 V AC 100...250 V)relayinput/output number 2 fast input FI0...FI114 digital input DI0...DI132 fast output FQ0...FQ18 digital output DQ0...DQ7discrete output current 2 A 4 A)5 ms opening contact digital output2 A 4 A)2 ms closing contact digital output300 mA2 ms fast output (normal mode)50 mA2 ms fast output (PWM or PTO mode)insulation resistance > 10 MOhm between the I/O and internal logic> 10 MOhm between power supply and earthmaximum output frequency 100 kHz fast output (PTO mode)1 kHz fast output (PWM mode)absolute accuracy error +/- 0.1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode)1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode)+/- 5 % of full scale cyclic ratio 10...90% fast output (PWM or PTO mode)+/- 10 % of full scale cyclic ratio 20...80% fast output (PWM or PTO mode)+/- 15 % of full scale cyclic ratio 30...70% fast output (PWM or PTO mode)height 2.95 in (74.95 mm)width 5.04 in (128 mm)depth 4.02 in (102 mm)Net Weight 1.13 lb(US) (0.512 kg)Environment standards IEC 61000-6-2FCC Class AWEEE directive 2002/96/ECUL 508EN 61131-2CSA C22.2 No 213 Class I Division 2RoHS China SJ/T 11363-2006RoHS compliantANSI/ISA 12-12-01product certifications CULus 508CUL 1604 Class 1 Division 2KCCC-tickCULus CSA 22-2 No 142GOSTmarking CEambient air temperature for operation 32…122 °F (0…50 °C)ambient air temperature for storage -4…140 °F (-20…60 °C)relative humidity 5…85 % without condensationoperating altitude <= 6561.68 ft (2000 m)storage altitude 0.00…32808.40 ft (0…10000 m)maximum pressure 800...1114 hPaIP degree of protection IP20 IEC 60529 rear panel)IP65 IEC 60529 front panel)NEMA degree of protection NEMA 4X front panelpollution degree 2 IEC 60664environmental characteristic Corrosive gas freeOrdering and shipping details Category 22568 - HMI CONTROLLERSDiscount Schedule MC2GTIN 00785901491781Nbr. of units in pkg. 1Package weight(Lbs) 2.57 lb(US) (1.17 kg)Returnability YesCountry of origin CNPacking Units Package 1 Height 4.02 in (10.200 cm)Package 1 width 7.48 in (19.000 cm)Package 1 Length 10.51 in (26.700 cm)Offer Sustainability Sustainable offer status Green Premium productCalifornia proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.govREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.Upgradeability -
View more
Documents
Language- All Languages22
- English17
- Chinese4
- French7
- German4
- Italian4
- Portuguese4
- Spanish6
CatalogFormatSizeDateAdd to My DocumentsCatalog Harmony SCU HMI controllers for simple machines English 04/20 (Version 5.0)DescriptionDiscover catalog for Harmony SCU HMI controllers for simple machinesprp.document.label.format pdfSize 2.9 MBDate 4/21/20DescriptionDiscover catalog for Harmony SCU HMI controllers for simple machinesDigest 178 Catalog 27: Automation Products (Version 1.0)DescriptionDigest 178 Section 27 contains selection information for programmable controllers, HMI products and software, SCADA/Distributed I/O products, network products, and Motion Control/HVAC/R controllers. Replaces Digest 177 section 27; 0100CT1501_SEC-27prp.document.label.format pdfSize 3.6 MBDate 5/12/19DescriptionDigest 178 Section 27 contains selection information for programmable controllers, HMI products and software, SCADA/Distributed I/O products, network products, and Motion Control/HVAC/R controllers. Replaces Digest 177 section 27; 0100CT1501_SEC-27prp.document.label.format pdfSize 3.3 MBDate 5/28/20User guideFormatSizeDateAdd to My DocumentsHarmony SCU HMI Controller, Hardware Guide (Version 08)DescriptionThe purpose of this document is to:- Show you how to install and operate your HMI controller.- Show you how to connect the HMI controller to a programming device equipped with SoMachine software.- Help you understand how to interface the HMI controller and other devices.- Help you become familiar with the HMI controller features.prp.document.label.format pdfSize 5.1 MBDate 9/1/20DescriptionThe purpose of this document is to:- Show you how to install and operate your HMI controller.- Show you how to connect the HMI controller to a programming device equipped with SoMachine software.- Help you understand how to interface the HMI controller and other devices.- Help you become familiar with the HMI controller features.Harmony SCU - HMI Controller, Quick Reference Guide (Version 04)DescriptionThis document contains information on installation, wiring principles, communication ports, data transfers, and driver installation for Magelis SCU HMI controllers.prp.document.label.format pdfSize 8.5 MBDate 11/1/19DescriptionThis document contains information on installation, wiring principles, communication ports, data transfers, and driver installation for Magelis SCU HMI controllers.Magelis SCU - HMI Controller, Programming guide (Version 06)DescriptionThe purpose of this document is to help you to configure and program your HMI SCU. For the programming of the HMI portion, please see the Vijeo-Designer online help which can be found in SoMachine.prp.document.label.format pdfSize 3.8 MBDate 12/1/16DescriptionThe purpose of this document is to help you to configure and program your HMI SCU. For the programming of the HMI portion, please see the Vijeo-Designer online help which can be found in SoMachine.Magelis SCU - HMI Controller, Quick Reference Guide (Version 00)DescriptionThis guide contains information on installation, wiring principles, grounding, and communication ports for Magelis SCU HMI controllers.prp.document.label.format pdfSize 7.8 MBDate 3/1/13DescriptionThis guide contains information on installation, wiring principles, grounding, and communication ports for Magelis SCU HMI controllers.prp.document.label.format pdfSize 5.5 MBDate 9/1/20prp.document.label.format pdfSize 4.1 MBDate 12/1/16prp.document.label.format pdfSize 5.3 MBDate 9/1/20prp.document.label.format pdfSize 3.7 MBDate 12/1/16CADFormatSizeDateAdd to My Documentsprp.document.label.format zipSize 16.3 MBDate 6/1/15Instruction SheetFormatSizeDateAdd to My DocumentsHarmony HMISTU and HMISCU Terminals ATEX/IECEx, Instruction Guide (Version 02)DescriptionThis present document applies when the Harmony HMISTU and HMISCU terminal bears Ex. marking and provides important information when used in hazardous areas.prp.document.label.format pdfSize 174.9 KBDate 5/1/20DescriptionThis present document applies when the Harmony HMISTU and HMISCU terminal bears Ex. marking and provides important information when used in hazardous areas.HMIZSURDP.. Remote Controller Module Connection Cable, Instruction Sheet (Version 01)DescriptionThis document contains installation instructions and diagrams for the HMIZSURDP remote controller module connection cable.prp.document.label.format pdfSize 1.1 MBDate 9/1/14DescriptionThis document contains installation instructions and diagrams for the HMIZSURDP remote controller module connection cable.China RoHS declarationFormatSizeDateAdd to My DocumentsHMISCU6A5 : 3”5 color touch controller panel - Dig 16 inputs/10 outputsDescription3”5 color touch controller panel - Dig 16 inputs/10 outputsprp.document.label.format pdfSize 195.3 KBDate 12/27/20Description3”5 color touch controller panel - Dig 16 inputs/10 outputsDeclaration of conformityFormatSizeDateAdd to My DocumentsDCE_HMISCU_STU_APR2019 (Version 00)DescriptionEU Declaration of Conformityprp.document.label.format pdfSize 2.3 MBDate 4/5/19DescriptionEU Declaration of ConformityEU RoHS DeclarationFormatSizeDateAdd to My DocumentsHMISCU6A5 : 3”5 color touch controller panel - Dig 16 inputs/10 outputsDescription3”5 color touch controller panel - Dig 16 inputs/10 outputsprp.document.label.format pdfSize 195.3 KBDate 12/27/20Description3”5 color touch controller panel - Dig 16 inputs/10 outputsMarine certificateFormatSizeDateAdd to My DocumentsMerchant_Navy_HMI_Instruction_Sheet (Version 13)DescriptionMerchant Navy Instruction Sheetprp.document.label.format pdfSize 149.3 KBDate 2/26/20DescriptionMerchant Navy Instruction SheetLR_C1210041E2_GTO_STO_SCU_STU_XBTGT (Version 1.0)DescriptionType Approval Certificate by Lloyd's Registerprp.document.label.format pdfSize 327.3 KBDate 4/24/17DescriptionType Approval Certificate by Lloyd's RegisterREACh DeclarationFormatSizeDateAdd to My DocumentsHMISCU6A5 : 3”5 color touch controller panel - Dig 16 inputs/10 outputsDescription3”5 color touch controller panel - Dig 16 inputs/10 outputsprp.document.label.format pdfSize 195.3 KBDate 12/27/20Description3”5 color touch controller panel - Dig 16 inputs/10 outputsSystem user guideFormatSizeDateAdd to My DocumentsCompact CANopen HMI Controller SCU (Version 00)Files in documentDescriptionThis document describes a generic architecture based on Magelis SCU HMI Controller and is intended to provide a quick introduction to the described system.prp.document.label.format zipSize 23 MBDate 3/1/15Files in documentDescriptionThis document describes a generic architecture based on Magelis SCU HMI Controller and is intended to provide a quick introduction to the described system. -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.